<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Circuit Breakers Online At Best Prices | Circuit Breaker</title>
	<atom:link href="https://payallelectrics.com/product-category/consumer/circuit-breaker/feed/" rel="self" type="application/rss+xml" />
	<link>https://payallelectrics.com/product-category/consumer/circuit-breaker/</link>
	<description>Suraksha Ka Wada</description>
	<lastBuildDate>Mon, 18 Nov 2024 10:56:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://payallelectrics.com/wp-content/uploads/2024/04/cropped-icon-logo-32x32.jpg</url>
	<title>Circuit Breakers Online At Best Prices | Circuit Breaker</title>
	<link>https://payallelectrics.com/product-category/consumer/circuit-breaker/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>RCCB (FOUR POLE) 100mA</title>
		<link>https://payallelectrics.com/product/rccb-four-pole-100ma/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 11 Jun 2024 09:23:18 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8680</guid>

					<description><![CDATA[<ul>
<li>Range: 25A, 40A, 63A</li>
<li>Sensitivities: 30mA, 100mA, 300mA</li>
<li>Execution: Double-Pole (2P), Four-Pole (4P)</li>
<li>Specification: IS12640 Part 1/IEC61008-1</li>
</ul>
<p>The post <a href="https://payallelectrics.com/product/rccb-four-pole-100ma/">RCCB (FOUR POLE) 100mA</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Time and again, we come across many mishaps disrupting human lives due to negligent use of electricity. A large number of industrial and domestic fires are attributed to and caused by electricity. Faulty insulated equipment or wrong usage of electrical devices cause current to flow the insulation to the earth. This is leakage current. This current poses two severe risk factors which are: fire risk &amp; electrocution risk. Residual current circuit breaker provides the function of isolation switching and earth leakage protection of electrical circuits. It also provides the indirect protection of the operator&#8217;s body against the dangerous effects of electric current.</p>
<p><strong>Working Principle of RCCB</strong></p>
<p>The RCCB function is based on Kirchhoff’s current law, explained below:</p>
<ul>
<li>If the vector sum of incoming current is equal to the vector sum of outgoing current, the RCCB will not trip</li>
<li>If the vector sum of incoming current is not equal to the vector sum of outgoing current, it indicates a leakage and the RCCB will trip</li>
</ul>
<p>Due to magnetic imbalance in the transformer of the RCCB, residual magnetism induces a current in the secondary winding coiled around the transformer core which acts on the trip relay. On reaching the trip value (dependent on the rated fault current), this current causes the armature of the magnetic trip to drop out.</p>
<p>The trip operates the lock which opens contacts by way of the energy stored within.</p>
<p>Consequently, all poles of the system are separated from the main system.</p>
<p>The drawn-in-switch-off characteristics of residual current devices with a rated fault current of 10 and 30 mA is proof that these are able to prevent the occurrence of dangerous heart chamber fibrillation. For this reason, residual current circuit breaker with the rated fault current of 10 mA is used for protection of particularly exposed individual equipment.</p>
<p>Residual current circuit breakers with 30 mA rated fault current are already specified for many areas (bathrooms with medical facilities, outside areas, agricultural land etc.)</p>
<p><strong>Sensitivity Selection Chart &#8211; RCCB</strong></p>
<p>30mA Tripping current designed for additional protection against direct contact or where specially required by the Indian wiring regulations. e.g.- sockets outside the equipotential zone TT systems, supply to caravan installation etc., the 30mA RCCB protects against leakage currents &amp; indirect contact with earth loop impedance up to 1667 Ohms; for use as additional protection against direct contact, residual tripping current must not exceed 30mA.</p>
<p>100mA Tripping current is suitable for protection against indirect contact &amp; leakage currents for larger installations; the 100mA RCCB operate within 30ms, but doesn’t provide the same level of personal protection as the 30mA units; the 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance up to 500 Ohms.</p>
<p><strong>Smart Features &amp; Benefits:</strong></p>
<ul>
<li>Provides protection against earth fault/leakage current and also fulfills the functional isolation.</li>
<li>Automatically measures and disconnects the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.</li>
<li>High short-circuit current withstand capacity – 6kA.</li>
<li>Dual termination possible for cable and comb type busbar connection.</li>
<li>Equipped with finger protection disconnection terminals (lP20).</li>
<li>Fire-resistant plastic parts to withstand abnormal heating and strong impact.</li>
<li>Independent of line voltage. Also free from external voltage fluctuation.</li>
<li>Incorporates a filtering device for prevention of nuisance tripping due to transient voltage.</li>
</ul>
<p>The post <a href="https://payallelectrics.com/product/rccb-four-pole-100ma/">RCCB (FOUR POLE) 100mA</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RCCB (DOUBLE POLE) 100mA</title>
		<link>https://payallelectrics.com/product/rccb-double-pole-100ma/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 11 Jun 2024 09:10:54 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8670</guid>

					<description><![CDATA[<ul>
<li>Range: 25A, 40A, 63A</li>
<li>Sensitivities: 30mA, 100mA, 300mA</li>
<li>Execution: Double-Pole (2P), Four-Pole (4P)</li>
<li>Specification: IS12640 Part 1/IEC61008-1</li>
</ul>
<p>The post <a href="https://payallelectrics.com/product/rccb-double-pole-100ma/">RCCB (DOUBLE POLE) 100mA</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Time and again, we come across many mishaps disrupting human lives due to negligent use of electricity. A large number of industrial and domestic fires are attributed to and caused by electricity. Faulty insulated equipment or wrong usage of electrical devices cause current to flow the insulation to the earth. This is leakage current. This current poses two severe risk factors which are: fire risk &amp; electrocution risk. Residual current circuit breaker provides the function of isolation switching and earth leakage protection of electrical circuits. It also provides the indirect protection of the operator&#8217;s body against the dangerous effects of electric current.</p>
<p><strong>Working Principle of RCCB</strong></p>
<p>The RCCB function is based on Kirchhoff’s current law, explained below:</p>
<ul>
<li>If the vector sum of incoming current is equal to the vector sum of outgoing current, the RCCB will not trip</li>
<li>If the vector sum of incoming current is not equal to the vector sum of outgoing current, it indicates a leakage and the RCCB will trip</li>
</ul>
<p>Due to magnetic imbalance in the transformer of the RCCB, residual magnetism induces a current in the secondary winding coiled around the transformer core which acts on the trip relay. On reaching the trip value (dependent on the rated fault current), this current causes the armature of the magnetic trip to drop out.</p>
<p>The trip operates the lock which opens contacts by way of the energy stored within.</p>
<p>Consequently, all poles of the system are separated from the main system.</p>
<p>The drawn-in-switch-off characteristics of residual current devices with a rated fault current of 10 and 30 mA is proof that these are able to prevent the occurrence of dangerous heart chamber fibrillation. For this reason, residual current circuit breaker with the rated fault current of 10 mA is used for protection of particularly exposed individual equipment.</p>
<p>Residual current circuit breakers with 30 mA rated fault current are already specified for many areas (bathrooms with medical facilities, outside areas, agricultural land etc.)</p>
<p><strong>Sensitivity Selection Chart &#8211; RCCB</strong></p>
<p>30mA Tripping current designed for additional protection against direct contact or where specially required by the Indian wiring regulations. e.g.- sockets outside the equipotential zone TT systems, supply to caravan installation etc., the 30mA RCCB protects against leakage currents &amp; indirect contact with earth loop impedance up to 1667 Ohms; for use as additional protection against direct contact, residual tripping current must not exceed 30mA.</p>
<p>100mA Tripping current is suitable for protection against indirect contact &amp; leakage currents for larger installations; the 100mA RCCB operate within 30ms, but doesn’t provide the same level of personal protection as the 30mA units; the 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance up to 500 Ohms.</p>
<p><strong>Smart Features &amp; Benefits:</strong></p>
<ul>
<li>Provides protection against earth fault/leakage current and also fulfills the functional isolation.</li>
<li>Automatically measures and disconnects the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.</li>
<li>High short-circuit current withstand capacity – 6kA.</li>
<li>Dual termination possible for cable and comb type busbar connection.</li>
<li>Equipped with finger protection disconnection terminals (lP20).</li>
<li>Fire-resistant plastic parts to withstand abnormal heating and strong impact.</li>
<li>Independent of line voltage. Also free from external voltage fluctuation.</li>
<li>Incorporates a filtering device for prevention of nuisance tripping due to transient voltage.</li>
</ul>
<p>The post <a href="https://payallelectrics.com/product/rccb-double-pole-100ma/">RCCB (DOUBLE POLE) 100mA</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RCCB (FOUR POLE) 30mA</title>
		<link>https://payallelectrics.com/product/rccb-four-pole-30ma/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 11 Jun 2024 08:58:45 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8659</guid>

					<description><![CDATA[<ul>
<li>Range: 25A, 40A, 63A</li>
<li>Sensitivities: 30mA, 100mA, 300mA</li>
<li>Execution: Double-Pole (2P), Four-Pole (4P)</li>
<li>Specification: IS12640 Part 1/IEC61008-1</li>
</ul>
<p>The post <a href="https://payallelectrics.com/product/rccb-four-pole-30ma/">RCCB (FOUR POLE) 30mA</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Time and again, we come across many mishaps disrupting human lives due to negligent use of electricity. A large number of industrial and domestic fires are attributed to and caused by electricity. Faulty insulated equipment or wrong usage of electrical devices cause current to flow the insulation to the earth. This is leakage current. This current poses two severe risk factors which are: fire risk &amp; electrocution risk. Residual current circuit breaker provides the function of isolation switching and earth leakage protection of electrical circuits. It also provides the indirect protection of the operator&#8217;s body against the dangerous effects of electric current.</p>
<p><strong>Working Principle of RCCB</strong></p>
<p>The RCCB function is based on Kirchhoff’s current law, explained below:</p>
<ul>
<li>If the vector sum of incoming current is equal to the vector sum of outgoing current, the RCCB will not trip</li>
<li>If the vector sum of incoming current is not equal to the vector sum of outgoing current, it indicates a leakage and the RCCB will trip</li>
</ul>
<p>Due to magnetic imbalance in the transformer of the RCCB, residual magnetism induces a current in the secondary winding coiled around the transformer core which acts on the trip relay. On reaching the trip value (dependent on the rated fault current), this current causes the armature of the magnetic trip to drop out.</p>
<p>The trip operates the lock which opens contacts by way of the energy stored within.</p>
<p>Consequently, all poles of the system are separated from the main system.</p>
<p>The drawn-in-switch-off characteristics of residual current devices with a rated fault current of 10 and 30 mA is proof that these are able to prevent the occurrence of dangerous heart chamber fibrillation. For this reason, residual current circuit breaker with the rated fault current of 10 mA is used for protection of particularly exposed individual equipment.</p>
<p>Residual current circuit breakers with 30 mA rated fault current are already specified for many areas (bathrooms with medical facilities, outside areas, agricultural land etc.)</p>
<p><strong>Sensitivity Selection Chart &#8211; RCCB</strong></p>
<p>30mA Tripping current designed for additional protection against direct contact or where specially required by the Indian wiring regulations. e.g.- sockets outside the equipotential zone TT systems, supply to caravan installation etc., the 30mA RCCB protects against leakage currents &amp; indirect contact with earth loop impedance up to 1667 Ohms; for use as additional protection against direct contact, residual tripping current must not exceed 30mA.</p>
<p>100mA Tripping current is suitable for protection against indirect contact &amp; leakage currents for larger installations; the 100mA RCCB operate within 30ms, but doesn’t provide the same level of personal protection as the 30mA units; the 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance up to 500 Ohms.</p>
<p><strong>Smart Features &amp; Benefits:</strong></p>
<ul>
<li>Provides protection against earth fault/leakage current and also fulfills the functional isolation.</li>
<li>Automatically measures and disconnects the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.</li>
<li>High short-circuit current withstand capacity – 6kA.</li>
<li>Dual termination possible for cable and comb type busbar connection.</li>
<li>Equipped with finger protection disconnection terminals (lP20).</li>
<li>Fire-resistant plastic parts to withstand abnormal heating and strong impact.</li>
<li>Independent of line voltage. Also free from external voltage fluctuation.</li>
<li>Incorporates a filtering device for prevention of nuisance tripping due to transient voltage.</li>
</ul>
<p>The post <a href="https://payallelectrics.com/product/rccb-four-pole-30ma/">RCCB (FOUR POLE) 30mA</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RCCB (DOUBLE POLE) 30mA</title>
		<link>https://payallelectrics.com/product/rccb-double-pole-30ma/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 11 Jun 2024 07:17:00 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8637</guid>

					<description><![CDATA[<ul>
<li>Range: 25A, 40A, 63A</li>
<li>Sensitivities: 30mA, 100mA, 300mA</li>
<li>Execution: Double-Pole (2P), Four-Pole (4P)</li>
<li>Specification: IS12640 Part 1/IEC61008-1</li>
</ul>
<p>The post <a href="https://payallelectrics.com/product/rccb-double-pole-30ma/">RCCB (DOUBLE POLE) 30mA</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Time and again, we come across many mishaps disrupting human lives due to negligent use of electricity. A large number of industrial and domestic fires are attributed to and caused by electricity. Faulty insulated equipment or wrong usage of electrical devices cause current to flow the insulation to the earth. This is leakage current. This current poses two severe risk factors which are: fire risk &amp; electrocution risk. Residual current circuit breaker provides the function of isolation switching and earth leakage protection of electrical circuits. It also provides the indirect protection of the operator&#8217;s body against the dangerous effects of electric current.</p>
<p><strong>Working Principle of RCCB</strong></p>
<p>The RCCB function is based on Kirchhoff’s current law, explained below:</p>
<ul>
<li>If the vector sum of incoming current is equal to the vector sum of outgoing current, the RCCB will not trip</li>
<li>If the vector sum of incoming current is not equal to the vector sum of outgoing current, it indicates a leakage and the RCCB will trip</li>
</ul>
<p>Due to magnetic imbalance in the transformer of the RCCB, residual magnetism induces a current in the secondary winding coiled around the transformer core which acts on the trip relay. On reaching the trip value (dependent on the rated fault current), this current causes the armature of the magnetic trip to drop out.</p>
<p>The trip operates the lock which opens contacts by way of the energy stored within.</p>
<p>Consequently, all poles of the system are separated from the main system.</p>
<p>The drawn-in-switch-off characteristics of residual current devices with a rated fault current of 10 and 30 mA is proof that these are able to prevent the occurrence of dangerous heart chamber fibrillation. For this reason, residual current circuit breaker with the rated fault current of 10 mA is used for protection of particularly exposed individual equipment.</p>
<p>Residual current circuit breakers with 30 mA rated fault current are already specified for many areas (bathrooms with medical facilities, outside areas, agricultural land etc.)</p>
<p><strong>Sensitivity Selection Chart &#8211; RCCB</strong></p>
<p>30mA Tripping current designed for additional protection against direct contact or where specially required by the Indian wiring regulations. e.g.- sockets outside the equipotential zone TT systems, supply to caravan installation etc., the 30mA RCCB protects against leakage currents &amp; indirect contact with earth loop impedance up to 1667 Ohms; for use as additional protection against direct contact, residual tripping current must not exceed 30mA.</p>
<p>100mA Tripping current is suitable for protection against indirect contact &amp; leakage currents for larger installations; the 100mA RCCB operate within 30ms, but doesn’t provide the same level of personal protection as the 30mA units; the 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance up to 500 Ohms.</p>
<p><strong>Smart Features &amp; Benefits:</strong></p>
<ul>
<li>Provides protection against earth fault/leakage current and also fulfills the functional isolation.</li>
<li>Automatically measures and disconnects the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.</li>
<li>High short-circuit current withstand capacity – 6kA.</li>
<li>Dual termination possible for cable and comb type busbar connection.</li>
<li>Equipped with finger protection disconnection terminals (lP20).</li>
<li>Fire-resistant plastic parts to withstand abnormal heating and strong impact.</li>
<li>Independent of line voltage. Also free from external voltage fluctuation.</li>
<li>Incorporates a filtering device for prevention of nuisance tripping due to transient voltage.</li>
</ul>
<p>The post <a href="https://payallelectrics.com/product/rccb-double-pole-30ma/">RCCB (DOUBLE POLE) 30mA</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCB Changeover Switch (FOUR POLE)</title>
		<link>https://payallelectrics.com/product/mcb-changeover-switch-four-pole/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 11 Jun 2024 06:21:39 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8607</guid>

					<description><![CDATA[<p>Payal MCB Changeover Switch is a manual operated changeover switch which finds its application in switching load between two power supplies. MCB Changeover switch finds wide applications in industries as</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-changeover-switch-four-pole/">MCB Changeover Switch (FOUR POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Payal MCB Changeover Switch is a manual operated changeover switch which finds its application in switching load between two power supplies. MCB Changeover switch finds wide applications in industries as well as in domestic area specially in Individual Bungalow(IB) for use in low voltage distribution circuits, wherever continuity of supply is necessary. It is used for switching to an alternate source of supply from main supply and vice – versa. The changeover switch comes in 2P and 4P versions, for single and three phase application respectively. It has three positions ( I-O-II) with centre-off. They are switch disconnectors with independent manual operation, capable of making, carrying and breaking currents under normal circuit conditions.</p>
<p><strong>COMPACT DESIGN</strong><br />
Compact size in line with Payal Mcb &amp; RCCB range</p>
<p><strong>FIRE RETARDANT</strong><br />
Fire Retardant Body materials ensure extra safety</p>
<p><strong>RELIABLE</strong><br />
AC22A operation ensure rigidity CE marking ensure Quality<br />
EASY TO USE<br />
Low operating force to operate 100% neutral allows to use any pole as neutral – Flexibity 35sqmm terminal capacity both for Al &amp; Cu Cables</p>
<p><strong>SAFE</strong><br />
IP 20 protection, Shrouded terminals, Clear indication of ON/OFF/ON on changeover switch shows the clear status</p>
<p><strong>HIGHLY DURABLE</strong><br />
Higher Electrical &amp; Mechanical life &gt; 10000 Operation</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-changeover-switch-four-pole/">MCB Changeover Switch (FOUR POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Isolator (FOUR POLE)</title>
		<link>https://payallelectrics.com/product/isolator-four-pole/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 11 Jun 2024 05:43:15 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8579</guid>

					<description><![CDATA[<p>Payal Isolators can be used as a main switch in wide variety of applications. These isolators are tested according to IEC / EN 60947-3 standards and fulfil the requirements for</p>
<p>The post <a href="https://payallelectrics.com/product/isolator-four-pole/">Isolator (FOUR POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Payal Isolators can be used as a main switch in wide variety of applications. These isolators are tested according to IEC / EN 60947-3 standards and fulfil the requirements for isolation function. Utilization category ensures possibility of switching mixed resistive and inductive loads with low overloads. Isolators are produced in modular design with width one module unit for all versions up to 4-pole.</p>
<p>The post <a href="https://payallelectrics.com/product/isolator-four-pole/">Isolator (FOUR POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCB (THREE POLE)</title>
		<link>https://payallelectrics.com/product/mcb-three-pole/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 11 Jun 2024 04:56:45 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8519</guid>

					<description><![CDATA[<p>Miniature Circuit Breakers are electromechanical devices which protect an electrical circuit from an overcurrent. The overcurrent, in an electrical circuit, may result from short circuit, overload or faulty design. A</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-three-pole/">MCB (THREE POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Miniature Circuit Breakers are electromechanical devices which protect an electrical circuit from an overcurrent. The overcurrent, in an electrical circuit, may result from short circuit, overload or faulty design. A MCB is a better alternative to a fuse since it does not require replacement, once an overload is detected. Unlike fuse, a MCB can be easily reset and thus offers improved operational safety and greater convenience without incurring large operating cost.</p>
<p><span style="font-size: 24;font-weight: bold">ON/OFF INDICATION</span><br />
Red &amp; Green flag indication provided below the knob gives indication of positive electrical ON/OFF contact status irrespective of mounting or knob position even from a<br />
distance.<br />
<span style="font-size: 24;font-weight: bold">BI-STABLE DIN CLIP</span><br />
Easy Mounting Strong hold on DIN Rail<br />
<span style="font-size: 24;font-weight: bold">13 PLATES ARC CHAMBER</span><br />
Quick &amp; Efficient Arc Quenching<br />
<span style="font-size: 24;font-weight: bold">BREAKING CAPACITY 10 KA</span><br />
<span style="font-size: 24;font-weight: bold">LOW POWER LOSS</span><br />
Power Loss values upto 70% lesser than specified by IEC/IS, making Payal MCB one of the most energy efficient MCB.<br />
<span style="font-size: 24;font-weight: bold">ERGONOMIC DOLLY</span><br />
Easy to Operate ON / OFF Marking to Know the status of MCB<br />
<span style="font-size: 24;font-weight: bold">EASY MCB EXTRACTION</span><br />
No dismantling of busbar to remove MCB – Unique mounting assembly allows to remove single MCB from shorting busbar without disturbing other MCBs.<br />
<span style="font-size: 24;font-weight: bold">IP 20 PROTECTION</span><br />
No accidental Contact/ Shock from live part during installation<br />
<span style="font-size: 24;font-weight: bold">ENERGY LIMITING CLASS 3</span><br />
Low let- through energy I T under short-circuit conditions ensures longer life of contacts and reduces thermal stresses in the distribution circuit.<br />
<span style="font-size: 24;font-weight: bold">LINE LOAD REVERSIBILITY</span><br />
The line or load can be connected to either side of the Payal MCB without any reduction in Performance.<br />
<span style="font-size: 24;font-weight: bold">AIR FLOW CHANNEL</span><br />
Reduces Body Temperature and keeping it cool to provide better performance<br />
<span style="font-size: 24;font-weight: bold">COMBI HEAD SCREW</span><br />
Ease of Clamping<br />
<span style="font-size: 24;font-weight: bold">NEUTRAL POLE PROTECTED</span><br />
Neutral pole is also protected against short circuit. So even if short circuit occurs at the<br />
neutral side, appliance or connected device will be protected.<br />
<span style="font-size: 24;font-weight: bold">MCB DURABILITY</span><br />
Electrical Life 6,000 Operation Tested Mechanical Life 10,000 Operation Tested</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-three-pole/">MCB (THREE POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCB (DOUBLE POLE)</title>
		<link>https://payallelectrics.com/product/mcb-double-pole/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 11 Jun 2024 04:40:21 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8493</guid>

					<description><![CDATA[<p>Miniature Circuit Breakers are electromechanical devices which protect an electrical circuit from an overcurrent. The overcurrent, in an electrical circuit, may result from short circuit, overload or faulty design. A</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-double-pole/">MCB (DOUBLE POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Miniature Circuit Breakers are electromechanical devices which protect an electrical circuit from an overcurrent. The overcurrent, in an electrical circuit, may result from short circuit, overload or faulty design. A MCB is a better alternative to a fuse since it does not require replacement, once an overload is detected. Unlike fuse, a MCB can be easily reset and thus offers improved operational safety and greater convenience without incurring large operating cost.</p>
<p><span style="font-size: 24;font-weight: bold">ON/OFF INDICATION</span><br />
Red &amp; Green flag indication provided below the knob gives indication of positive electrical ON/OFF contact status irrespective of mounting or knob position even from a<br />
distance.<br />
<span style="font-size: 24;font-weight: bold">BI-STABLE DIN CLIP</span><br />
Easy Mounting Strong hold on DIN Rail<br />
<span style="font-size: 24;font-weight: bold">13 PLATES ARC CHAMBER</span><br />
Quick &amp; Efficient Arc Quenching<br />
<span style="font-size: 24;font-weight: bold">BREAKING CAPACITY 10 KA</span><br />
<span style="font-size: 24;font-weight: bold">LOW POWER LOSS</span><br />
Power Loss values upto 70% lesser than specified by IEC/IS, making Payal MCB one of the most energy efficient MCB.<br />
<span style="font-size: 24;font-weight: bold">ERGONOMIC DOLLY</span><br />
Easy to Operate ON / OFF Marking to Know the status of MCB<br />
<span style="font-size: 24;font-weight: bold">EASY MCB EXTRACTION</span><br />
No dismantling of busbar to remove MCB – Unique mounting assembly allows to remove single MCB from shorting busbar without disturbing other MCBs.<br />
<span style="font-size: 24;font-weight: bold">IP 20 PROTECTION</span><br />
No accidental Contact/ Shock from live part during installation<br />
<span style="font-size: 24;font-weight: bold">ENERGY LIMITING CLASS 3</span><br />
Low let- through energy I T under short-circuit conditions ensures longer life of contacts and reduces thermal stresses in the distribution circuit.<br />
<span style="font-size: 24;font-weight: bold">LINE LOAD REVERSIBILITY</span><br />
The line or load can be connected to either side of the Payal MCB without any reduction in Performance.<br />
<span style="font-size: 24;font-weight: bold">AIR FLOW CHANNEL</span><br />
Reduces Body Temperature and keeping it cool to provide better performance<br />
<span style="font-size: 24;font-weight: bold">COMBI HEAD SCREW</span><br />
Ease of Clamping<br />
<span style="font-size: 24;font-weight: bold">NEUTRAL POLE PROTECTED</span><br />
Neutral pole is also protected against short circuit. So even if short circuit occurs at the<br />
neutral side, appliance or connected device will be protected.<br />
<span style="font-size: 24;font-weight: bold">MCB DURABILITY</span><br />
Electrical Life 6,000 Operation Tested Mechanical Life 10,000 Operation Tested</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-double-pole/">MCB (DOUBLE POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCB (SINGLE POLE)</title>
		<link>https://payallelectrics.com/product/mcb-single-pole/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Mon, 10 Jun 2024 11:20:09 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8478</guid>

					<description><![CDATA[<p>Miniature Circuit Breakers are electromechanical devices which protect an electrical circuit from an overcurrent. The overcurrent, in an electrical circuit, may result from short circuit, overload or faulty design. A</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-single-pole/">MCB (SINGLE POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Miniature Circuit Breakers are electromechanical devices which protect an electrical circuit from an overcurrent. The overcurrent, in an electrical circuit, may result from short circuit, overload or faulty design. A MCB is a better alternative to a fuse since it does not require replacement, once an overload is detected. Unlike fuse, a MCB can be easily reset and thus offers improved operational safety and greater convenience without incurring large operating cost.</p>
<p><span style="font-size: 24; font-weight: bold;">ON/OFF INDICATION</span><br />
Red &amp; Green flag indication provided below the knob gives indication of positive electrical ON/OFF contact status irrespective of mounting or knob position even from a<br />
distance.<br />
<span style="font-size: 24; font-weight: bold;">BI-STABLE DIN CLIP</span><br />
Easy Mounting Strong hold on DIN Rail<br />
<span style="font-size: 24; font-weight: bold;">13 PLATES ARC CHAMBER</span><br />
Quick &amp; Efficient Arc Quenching<br />
<span style="font-size: 24; font-weight: bold;">BREAKING CAPACITY 10 KA</span><br />
<span style="font-size: 24; font-weight: bold;">LOW POWER LOSS</span><br />
Power Loss values upto 70% lesser than specified by IEC/IS, making Payal MCB one of the most energy efficient MCB.<br />
<span style="font-size: 24; font-weight: bold;">ERGONOMIC DOLLY</span><br />
Easy to Operate ON / OFF Marking to Know the status of MCB<br />
<span style="font-size: 24; font-weight: bold;">EASY MCB EXTRACTION</span><br />
No dismantling of busbar to remove MCB – Unique mounting assembly allows to remove single MCB from shorting busbar without disturbing other MCBs.<br />
<span style="font-size: 24; font-weight: bold;">IP 20 PROTECTION</span><br />
No accidental Contact/ Shock from live part during installation<br />
<span style="font-size: 24; font-weight: bold;">ENERGY LIMITING CLASS 3</span><br />
Low let- through energy I T under short-circuit conditions ensures longer life of contacts and reduces thermal stresses in the distribution circuit.<br />
<span style="font-size: 24; font-weight: bold;">LINE LOAD REVERSIBILITY</span><br />
The line or load can be connected to either side of the Payal MCB without any reduction in Performance.<br />
<span style="font-size: 24; font-weight: bold;">AIR FLOW CHANNEL</span><br />
Reduces Body Temperature and keeping it cool to provide better performance<br />
<span style="font-size: 24; font-weight: bold;">COMBI HEAD SCREW</span><br />
Ease of Clamping<br />
<span style="font-size: 24; font-weight: bold;">NEUTRAL POLE PROTECTED</span><br />
Neutral pole is also protected against short circuit. So even if short circuit occurs at the<br />
neutral side, appliance or connected device will be protected.<br />
<span style="font-size: 24; font-weight: bold;">MCB DURABILITY</span><br />
Electrical Life 6,000 Operation Tested Mechanical Life 10,000 Operation Tested</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-single-pole/">MCB (SINGLE POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MCB Changeover Switch (DOUBLE POLE)</title>
		<link>https://payallelectrics.com/product/mcb-changeover-switch-double-pole/</link>
		
		<dc:creator><![CDATA[payal]]></dc:creator>
		<pubDate>Tue, 14 May 2024 10:28:24 +0000</pubDate>
				<guid isPermaLink="false">http://www.payallelectrics.com//?post_type=product&#038;p=8172</guid>

					<description><![CDATA[<p>Payal MCB Changeover Switch is a manual operated changeover switch which finds its application in switching load between two power supplies. MCB Changeover switch finds wide applications in industries as</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-changeover-switch-double-pole/">MCB Changeover Switch (DOUBLE POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Payal MCB Changeover Switch is a manual operated changeover switch which finds its application in switching load between two power supplies. MCB Changeover switch finds wide applications in industries as well as in domestic area specially in Individual Bungalow(IB) for use in low voltage distribution circuits, wherever continuity of supply is necessary. It is used for switching to an alternate source of supply from main supply and vice – versa. The changeover switch comes in 2P and 4P versions, for single and three phase application respectively. It has three positions ( I-O-II) with centre-off. They are switch disconnectors with independent manual operation, capable of making, carrying and breaking currents under normal circuit conditions.</p>
<p><strong>COMPACT DESIGN</strong><br />
Compact size in line with Payal Mcb &amp; RCCB range</p>
<p><strong>FIRE RETARDANT</strong><br />
Fire Retardant Body materials ensure extra safety</p>
<p><strong>RELIABLE</strong><br />
AC22A operation ensure rigidity CE marking ensure Quality<br />
EASY TO USE<br />
Low operating force to operate 100% neutral allows to use any pole as neutral – Flexibity 35sqmm terminal capacity both for Al &amp; Cu Cables</p>
<p><strong>SAFE</strong><br />
IP 20 protection, Shrouded terminals, Clear indication of ON/OFF/ON on changeover switch shows the clear status</p>
<p><strong>HIGHLY DURABLE</strong><br />
Higher Electrical &amp; Mechanical life &gt; 10000 Operation</p>
<p>The post <a href="https://payallelectrics.com/product/mcb-changeover-switch-double-pole/">MCB Changeover Switch (DOUBLE POLE)</a> appeared first on <a href="https://payallelectrics.com">Payall Electrics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
